WEATHER ↗A–Z
Part 02 · Solar school

The science of off-grid sunshine.

What a 200W roof panel really does in the UK, how MPPT changes the game, and why solar production is not the same as charging current.

AI-generated illustrative scene
AI illustration · NIX learning series

The solar panel is not the battery charger

Vanilla carries a 200W roof-mounted PV Logic solar panel, feeding a Victron SmartSolar MPPT 75/15. The panel makes DC electricity when light falls on its cells; the MPPT controller adapts that electricity to a suitable voltage and current for the leisure battery. The SmartShunt then measures the net battery flow, after loads and charging have had their say.

That distinction explains one of the most puzzling readings in a van. Your solar app can report useful output while the shunt reports discharge. Nothing needs to be broken: the fridge, lights, heater electronics and other loads may simply be using more than the panels are giving.

Device The question it answers What it cannot tell you on its own
200W solar panel How much light-derived electricity is potentially available? Actual usable battery charge
SmartSolar 75/15 What is the solar charger delivering? How much all appliances are consuming
SmartShunt Is the leisure battery gaining or losing charge overall? Which charging source supplied each amp
Fogstar BMS What does the battery's internal management system report? Complete campervan circuit-level energy use

NIX rule: Solar production and battery charging are not interchangeable figures. Always look at both the MPPT and the shunt.

What does a 200W panel actually mean?

The advertised wattage is a nameplate rating under defined laboratory test conditions—not a promise that a roof panel will deliver 200W all afternoon on a British November campsite. Real production depends on the angle of sunlight, cloud, season, cell temperature, dirt, shading, wiring losses and the controller's operating conditions.

A helpful illustrative equation is power (W) = voltage (V) × current (A). If the solar charger can supply 120W to a battery operating around 13.5V, that is approximately 8.9A of charger output before considering the rest of the van's loads. It is a worked example, not a measurement from Vanilla.

The MPPT designation 75/15 means a controller in the 75V solar-input class and a maximum nominal battery-charging current of 15A; it does not mean it delivers 75A or always produces 15A. Design limits and component pairing must follow Victron specifications.

Sunlight, shade and the British weather

Think of four different situations:

  1. Bright summer midday: Strong solar input is possible, but the panel's actual power still depends on its position and temperature.
  2. Bright overcast day: Diffuse light can produce useful power even without a visible hard-edged shadow.
  3. Low winter sun: Shorter days, lower solar angles and roof shadows can substantially reduce total daily harvest.
  4. One shaded patch: Depending on module construction and bypass diodes, a small shadow can disproportionately affect output.

A panel fitted flat to a pop-top or roof has a wonderfully convenient installation, but does not track the sun. Parking under trees may be excellent for comfort, yet poor for solar generation. In autumn, that matters: the difference between a bright open pitch and a deeply shaded pitch can decide whether the fridge runs mainly from harvested power or stored battery energy.

The three numbers I check together

Open VictronConnect and look at the SmartSolar. Note its reported charging power or current. Then open the SmartShunt and look at its current and SOC.

Consider a fictional worked example, chosen to show the maths:

Source or load Current
Solar controller output +8A
Combined campervan loads −3A
Result at the battery +5A

Now a cloud reduces solar output to 1A, while those appliances still need 3A. Net battery flow becomes −2A. The panel is still working. The battery is discharging. Both statements can be true.

This subtraction is an approximation assuming the currents are referenced to the same battery-side voltage and no relevant paths bypass the shunt.

Why the CSV is interesting—but not a solar meter

The supplied export contains 888 valid hourly observations, labelled Charge (Ah) and SOC (%), from 6 October to 12 November 2026. It does not contain MPPT history, solar wattage, starter-battery data, charger-identification fields or weather observations.

The signed charge values tend to be more positive in late morning and around midday than overnight. That pattern is consistent with periods when charging is available, but it cannot prove the power came from the roof panel. Vanilla can also charge while driving or on mains hookup.

For the clearest solar analysis in future, export SmartSolar history for the same dates and compare battery SOC, MPPT yield, charge-source status and whether the engine or EHU was active. The two data streams together tell a much stronger story.

Reading the MPPT's own status

A Victron solar controller may display charging stages such as Bulk, Absorption and Float. These indicate how its charging control is operating. They are not three fixed SOC percentages and should not be treated as a direct battery fuel gauge.

  • Bulk: The charger supplies available current while raising battery voltage toward its absorption target, subject to limits and battery acceptance.
  • Absorption: The controller holds an absorption-voltage target and charge current typically tapers as the battery approaches full, depending on battery and system behaviour.
  • Float: The charger moves to a lower maintenance voltage according to the battery profile.

For a Fogstar Drift lithium battery, Fogstar publishes around 14.2V absorption and 13.5V float as recommended Victron charger custom settings. Refer to the instructions for your particular battery and charger, especially where the label, model revision or firmware differs. Never confuse these charging setpoints with the SmartShunt's charged-voltage detection threshold.

Why a panel can produce almost nothing at 100% SOC

This catches people out. If a sufficiently charged battery does not need significant current, the charge controller may reduce output. A small panel-output number while the battery is full is not automatically evidence of failed solar hardware. Equally, the same small output at 40% SOC in bright sunshine could be worth investigating.

Always interpret production alongside battery voltage, battery SOC, charge stage, solar conditions and current loads.

Seven small habits that make solar more useful

  1. Keep the panel reasonably clean and inspect for obvious damage using safe access methods.
  2. Park with sun exposure in mind, without sacrificing safety or local parking rules.
  3. Check that VictronConnect reports the SmartSolar as connected and behaving plausibly.
  4. Know that 200W panel rating is not 200W guaranteed production.
  5. Track the battery's overnight SOC drop, not just a pleasing midday charging spike.
  6. Compare cloud-free days and poor-weather days over several weeks.
  7. Plan driving or EHU as backup when a multi-day trip meets winter weather.

NIX's takeaway

The panel is the energy collector. The MPPT is the intelligent charging controller. The SmartShunt is the accountant. The Fogstar battery is the energy store. Treat them as four different jobs, and the whole system becomes far easier to understand.

Continue: Solar charging joins the other sources in the charging guide, or open the actual battery readings.

Manufacturer references: Victron SmartShunt manual, Fogstar Drift charging advice.

SUNNY / CLOUDY — ILLUSTRATIVE EXAMPLESBRIGHT SUNLIGHT ☀CLOUDY CONDITIONS ☁+8A solar+1A solar−3A loads−3A loads+5A battery−2A battery
Correct arithmetic with hypothetical numbers. This is not drawn from the CSV and does not attribute any real charge event to solar.

Try it yourself: solar versus loads

Slide the figures and watch what the battery actually sees. These are hypothetical currents, not live readings.

Net current at battery+5.0A
The battery is charging because solar exceeds the loads.

A simplified battery-side current balance; ignores voltage differences and losses. Actual battery behaviour and source limits may be different.