Part 05 · Practical energy audit

Will you make it through the night?

Understand the consumption of a fridge, diesel heater, lights and gadgets—and plan a night away with an interactive watt-hour calculator.

AI-generated illustrative scene
AI illustration · NIX learning series

The question to ask before every overnight stop

Campervan electricity becomes much less mysterious when you ask a simple question: how many watt-hours will tonight's equipment use, and what do I have available? It is the same planning principle as knowing how far the diesel tank will take you—except the energy is shared across a fridge, heater controls, lights, pumps and charging gadgets.

Vanilla has a 105Ah Fogstar LiFePO₄ leisure battery. Using 12.8V as a simplified nominal voltage, its theoretical nominal energy is 1,344Wh. Not all of that should automatically be treated as available for a planned night. Allow for a reserve, system losses, load variation and the difference between the monitor's estimated SOC and real battery capacity.

The interactive calculator below is deliberately straightforward. It helps plan a night, but cannot predict compressor-fridge duty cycles, a diesel heater's starting demand or exactly how many amps a partly shaded solar panel will deliver.

A quick guide to appliance energy

Energy consumption is power × time. This matters more than just looking at an appliance's headline wattage.

A 25W device used continuously for 10 hours consumes 250Wh. A 50W compressor motor that runs only 25% of the time during the same ten hours consumes 125Wh. The second appliance is rated at twice the running wattage but can use half the total energy if its duty cycle is lower.

That is why fridge consumption needs to be estimated or measured over time, not inferred from the maximum or momentary current alone.

Four loads to think about on Vanilla

The 50-litre compressor fridge

The fridge is the classic quiet, persistent consumer. Its compressor cycles according to thermostat setting, ambient temperature, ventilation, how often the door opens and how much warm food is added. Rather than pretending it has a single fixed all-day wattage, measure it over a representative 24-hour period if possible.

Diesel heater electronics

The Webasto heater burns diesel for heat, but uses electricity for controls, fan and start-up activity. Its electrical draw can vary as it ignites, ramps up, maintains temperature or cycles. The heat output in kilowatts is not the same as the electrical demand placed on the leisure battery.

Lighting, pumps and USB charging

Individually small appliances can add up when used for hours, especially if charging a laptop or other device via a converter. Check the actual supply path: a USB charger, a Jackery output and a 12V socket do not all have identical losses or wiring arrangements.

Portable power-station charging

A Jackery connected to the 12V leisure system is another battery being charged from your leisure battery. That is not free energy; when it draws power, the SmartShunt should see the effect if the negative return path is monitored correctly.

The 'SOC at bedtime' calculation

For simple planning, start with the current estimated SOC and deduct the energy your night is expected to consume. At a nominal 105Ah capacity:

Available amp-hours above a 10% reserve = 105 × (current SOC − 10%).

If the shunt reads 76%, that leaves roughly 69.3Ah between the displayed charge and a 10% reserve, before accounting for limitations and uncertainty. At 12.8V this corresponds to approximately 887Wh as a planning estimate—not a promise of deliverable energy.

The battery does not have to reach 10% to be 'empty': the 10% figure is a planning reserve chosen by the operator, not the internal BMS trip point.

Why 'time to go' isn't a crystal ball

VictronConnect estimates time remaining based on load behaviour and your configured discharge floor. That can fluctuate wildly in a campervan. The fridge stops: projected time jumps up. The heater ignites: it drops. The sun comes out: it may become irrelevant during net charging.

For a planned night, use expected energy consumption over the entire period, then compare it to available energy. Look at the time-to-go reading as supporting context.

A proper 24-hour NIX energy audit

Start at roughly the same time on two consecutive days. Note the SmartShunt SOC, charger status and current; record whether the vehicle is parked, driving or connected to EHU. Keep a simple log of major appliances and their operating modes.

If you want to estimate what the fridge alone uses, isolate other variable loads only where it is safe and practical, and measure over a period long enough to include multiple compressor cycles. The SmartShunt cannot identify which appliance took an amp: it reports the battery's net current.

The information worth writing down

Observation Why it matters
SOC at start and finish Identifies estimated charge change
Current at representative times Shows whether the system is charging or discharging
MPPT yield and status Helps separate solar contribution from battery use
Engine operating / Orion status Distinguishes driving charge events
Mains/EHU charger status Identifies externally supplied charge
Major loads Explains changes in overnight consumption
Ambient conditions Helps interpret fridge and heater usage

A campsite example: a gloomy November evening

Illustrative scenario, not a claim about a specific logged journey. You arrive at 5pm after a cloudy drive. The solar panel is producing very little, the fridge has been on all day and the shunt shows a comfortable battery reserve. It would be easy to say 'that'll do'.

Instead, estimate the energy needed through the night. If the heater electronics and fridge will both be busy and tomorrow's forecast is poor, leave a bigger reserve and plan how to top up. The purpose of the SmartShunt is not to make you watch numbers every ten minutes; it is to let you make one informed decision and then enjoy the evening.

What this calculator deliberately cannot know

The simulator cannot know actual battery health, BMS restrictions, converter losses, battery temperature, current shunt calibration, fridge duty cycles, accurate weather forecasts or charging-source status. It does not replace the actual monitor. If the battery is approaching a genuinely low state of charge, use the real equipment's readings and safety guidance, not a web estimate.

Continue: Lithium fundamentals, the NIX Power Lab, and settings & troubleshooting.

Interactive overnight-energy calculator

These starting values are examples only. Change them to measured watts and realistic use times for your own kit.

Appliance (example)Running wattsHoursDuty cycle %
Fridge compressor
Diesel heater electrics
LED lighting
USB / small electronics
Illustrative overnight load282WhPredicted SOC 59.4%Above your chosen reserve in this simplified model.

Assumes no incoming charge, 105Ah × 12.8V nominal, idealised DC consumption and fixed duty cycles. Does not include conversion losses, BMS operation or changing temperatures. Do not use as the sole basis for electrical safety decisions.