A damp, near-freezing Staffordshire dawn.
The great
cold-night
showdown.
One campervan. One living room. Three tiny sensors. And a frosty Staffordshire night that revealed two very different stories about staying warm.
One night. Three temperatures.
All readings below come from three separate SwitchBot exports, matched to the same minute.
Webasto set to 20°C. Comfortably warm throughout the overnight comparison.
After an evening at 21.7°C, the room had gradually cooled overnight.
What follows is the more forensic version of the story: less “it was warm”, more why it was warm, what the controls were doing, what a falling temperature curve means and what the data can never tell us on its own. Every figure labelled measured comes from the exported SwitchBot readings; every hypothesis is clearly identified.
Not just a test. A confidence check.
After frustrating problems with the diesel heater in my campervan, Vanilla, I wanted something more convincing than "it seems to be working". So I left the Webasto set to 20°C and let the sensors do the talking.
At the same time, I had readings from the living room at home and another sensor outside. That gave me a rather wonderful experiment: three places experiencing the same cold night, but responding to it in completely different ways.
That dramatic reversal isn't a verdict on which is better insulated. It is a story about heating strategy: the Webasto was being asked to hold warmth, while the home system was operating around a lower overnight setting.

Despite outside cooling steadily, Vanilla finished warmer than it started.
The room cooled most quickly early in the night, then much more slowly towards morning.
Don't take my word for it.
Watch the lines.
This interactive chart is drawn from the actual CSV sensor readings, not AI-generated artwork. Move your finger or mouse over it, or hit Replay.
Three temperatures, one timeline
Temperatures in °C · 1-minute original samples · exact timestamps
Live inspection means the chart responds to your interaction; these are historical readings, not a connection to the sensors. Full-day chart displays the exact common overlap from 06:57 Friday to 06:09 Saturday.
Five moments that
tell the story.
Vanilla: 15.6°C
The campervan was below the 20°C setting, just before its rapid evening rise.
Vanilla: 20.1°C
Up 4.5°C in 34 minutes. That's roughly 7.9°C per hour across that interval.
Vanilla takes the lead
The van's sensor first equalled or exceeded the living-room sensor.
Vanilla: 23.0°C
A 3°C overshoot above the selected Webasto setting, worth investigating.
22.6° · 16.3° · 1.0°
Vanilla, living room and outside. Three numbers, one striking contrast.
The house was warm.
Then the schedule changed.
The living room peaked at 24.3°C at 14:55 Friday, then entered a long cooling phase. Here's how the overnight decline unfolded.
Each bar shows the absolute temperature drop, not energy consumed. The corresponding average cooling rates were about 1.10, 0.47 and 0.30°C/hour.
A room doesn't cool at a constant rate. As the indoor–outdoor temperature difference narrows, heat loss often slows too, assuming everything else is unchanged.
Your previously reported Tado schedule was 20.5°C daytime / 17°C night-time, with the thermostat in the hall rather than the living room. The overnight profile is broadly consistent with a night setback, but the CSV doesn't record actual Tado calls for heat.
That distinction matters: the room's 16.1°C minimum at 05:58 doesn't automatically mean a failed thermostat. The hall and living room may simply have different temperatures.
Not one reading. 550 of them.
A screenshot tells you how warm a room was. A time series tells you how the heating system behaved. Here's the properly nerdy version of the comparison, distilled so you don't need a statistics degree.
21.94°C
Mean temperature from 9pm to 6:09am. Median: 22.1°C. Lowest: 20.1°C.
18.00°C
Mean overnight temperature. Median: 17.6°C. The room cooled gradually from its evening peak.
2.27°C
Average outside during the comparison. Minimum: 1.0°C, exactly at the final sample.
The details hiding in the averages
62.4%
of Vanilla's recorded minutes were at 22°C or warmer — 343 of 550 samples. A 20°C controller setting is not the same as the temperature at every point in a cabin.
180 min
of living-room readings were below 17°C. The hall-mounted Tado thermostat and the living-room SwitchBot were not necessarily reading the same air.
When did Vanilla pull ahead?
This chart shows Vanilla minus living room. Above zero, the campervan was warmer. Below zero, the living room was warmer. The line is calculated from the actual matching timestamps, not an AI illustration.
-2°+0°+2°+4°+6°+8°21:0000:0003:0006:0006:09By morning: +6.3°CHourly comparison points, plus the final 06:09 reading. Vanilla caught up at 21:41. The largest observed gap was +6.5°C at 05:58. The finish was +6.3°C.
Temperature stability
Vanilla's overnight standard deviation was 0.64°C; the living room's was 1.49°C. That measures the spread of the recorded readings.
It does not prove the Webasto regulates more accurately. A room intentionally cooling towards 17°C will naturally have a larger spread than a heated van hovering near 22°C.
What “550 samples” really means
There are 550 one-minute observations per sensor across 549 elapsed minutes, from 21:00 to 06:09 inclusive. Adjacent observations are correlated: 550 samples do not equal 550 independent heating experiments.
SwitchBot exports report temperatures in tenths of a degree, so a line that's perfectly flat for several minutes may simply be hidden variation smaller than the display resolution.
Open the hour-by-hour source table
| Time | Vanilla °C | Room °C | Outside °C | Van − room |
|---|---|---|---|---|
| Fri 21:00 | 20.1 | 21.7 | 3.4 | -1.6 |
| Fri 22:00 | 21.1 | 20.4 | 3.2 | +0.7 |
| Fri 23:00 | 21.6 | 19.2 | 2.8 | +2.4 |
| Sat 00:00 | 22.1 | 18.4 | 2.6 | +3.7 |
| Sat 01:00 | 22.3 | 17.8 | 2.5 | +4.5 |
| Sat 02:00 | 22.6 | 17.4 | 2.2 | +5.2 |
| Sat 03:00 | 21.8 | 17.0 | 2.0 | +4.8 |
| Sat 04:00 | 21.2 | 16.7 | 1.6 | +4.5 |
| Sat 05:00 | 22.4 | 16.5 | 1.4 | +5.9 |
| Sat 06:00 | 22.6 | 16.1 | 1.1 | +6.5 |
| Sat 06:09 | 22.6 | 16.3 | 1.0 | +6.3 |
Every displayed cell comes from the original CSV reading at the listed minute. More granular data remains inside the chart and downloadable package.
Where does all the heat actually go?
Heat doesn't simply vanish. Warm air and warm surfaces release energy to colder surroundings. A heater's job is to replace that energy fast enough to hold the temperature you want.
Webasto, radiators, DREO or Vortex add energy to a space.
Air, seats, furniture, walls and cabinets store thermal energy.
Windows, roof, floor, ventilation and leaks transfer heat away.
Translation: the rate at which temperature changes depends on heat added, minus heat escaping, divided by how much thermal mass must be warmed. C represents effective heat capacity; UA is the overall heat-loss coefficient; dT/dt means the temperature change per unit time.
This is a simplified one-zone model. Real rooms and vans have multiple surfaces, air currents, solar gains and ventilation paths, so it is a teaching tool rather than a calibrated model of Vanilla.
Why the room cooled faster at first
Between 21:00 and midnight it fell 3.3°C, versus 1.4°C during the following three hours. When the room is much warmer than outside, the temperature difference drives greater heat loss. As that difference narrows, the loss often slows.
But radiators, thermostatic valves and hidden heat gains could also influence this curve. It cannot be used to isolate the building's insulation without heater on/off data.
Why a small van can warm quickly
Vanilla rose from 15.6°C at 20:15 to 20.1°C at 20:49: 4.5°C in 34 minutes, or 7.94°C/hour across that interval.
There's less enclosed air than in a house, though seats, cabinets and the vehicle structure still absorb heat. A fast sensor response is encouraging, but it does not reveal the heater's instantaneous 2 kW output or the heat stored in the van's structure.
The “degree-hour” trick
We can measure how much warmer each space remained than outside over time. Imagine adding up every minute of its inside-minus-outside difference. That's a temperature-exposure quantity in degree-hours, not energy consumption.
Trapezoidal integration across the exact 549 elapsed minutes, using the original one-minute measurements. These numbers describe the indoor–outdoor temperature gap accumulated over time. They do not reveal fuel, electricity, U-values, efficiency or thermal capacity.
Extra geekery: what's the theoretical effect of a 1°C temperature change?
The interesting bit
isn't just temperature.
The moisture story
Relative humidity looks ordinary in both spaces. But the actual quantity of water vapour tells a richer story.
| Overnight average | Living room | Vanilla |
|---|---|---|
| Relative humidity | 39.5% | 44.8% |
| Absolute humidity | 6.09 g/m³ | 8.66 g/m³ |
| Dew point | 4.0°C | 9.4°C |
At a dew point around 9.4°C, condensation could form on a surface colder than that, such as glazing or bare metal. This is a risk indicator, not proof that condensation occurred.
Why 20°C can mean 22°C
Vanilla's Webasto was selected at 20°C; its SwitchBot sensor averaged 21.94°C between 21:00 and 06:09.
Possible contributors include different sensor locations, stratified air, delayed control response and residual heat. The recording shows temperature variations, but not the burner state, fuel-pump pulses or actual fuel use.


✦ Open the full AI editorial storyboard (decorative artwork, not source data)

Artwork may stylise vehicles, rooms, timelines and graphs. Only the interactive charts and written measurements in this article should be treated as the sensor-data record.
Set to 20°C. Reads 22°C.
Fault, feature or sensor location?
Now for the interesting control-systems bit. Your diesel heater has its own temperature feedback loop. The SwitchBot is a separate witness watching from another point in the van.
20°C
The requested Webasto controller setting, as you confirmed.
21.94°C
The independent sensor's overnight average, not the heater's own feedback reading.
+1.94°C
Average observed offset from the selected setting. Not necessarily thermostat calibration error.
How the heater actually regulates
The heater measures intake air via its internal sensor or a compatible external room sensor.
It varies its fan speed and metering-pump fuel delivery as heating demand changes.
At minimum output it can stop combustion during a control pause, then restart when its sensor cools.
This is described in the Webasto Air Top 2000 STC workshop manual, section 3.3–3.5; it explains a possible mechanism, not what definitely happened inside Vanilla. Read the workshop manual ↗
Event A · 02:20–02:30
−1.5°CVanilla went from 22.6°C down to 21.1°C over 10 minutes. Outside held at 2.2°C at both ends. This looks like a local cooling episode, but the fuel pump and fan weren't logged.
Possible explanations: a control pause, airflow change or a sensor exposed to briefly cooler air.
Event B · 03:47–04:02
−1.8°CFrom the overnight peak of 23.0°C to 21.2°C in 15 minutes, while outside dropped from 1.8°C to 1.6°C.
This is another candidate for a control-state change, but a graph of air temperature alone cannot tell us whether the burner stopped.
What about the previous fuel-system troubles?
After the repair, this run gives reassuring evidence that the cabin received sustained heat. But the exported data contain no combustion signal, no pump pulse log, no error-code record and no exhaust or battery-voltage trace. It would be premature to call the fuel system permanently reliable on that basis alone.
What the readings support
Rapid recovery, high cabin temperature and repeated warming after cooling dips are consistent with an effective heat source across the test.
What the engineer still needs to finish
The reported cable-tie pump mounting should be checked and replaced with the ordered appropriate vibration-damped mount. Webasto's installation documentation specifically requires a vibration-damping mounting and a suitable pump orientation. Have the professional verify this and the fuel connections.
Warmth is one thing.
What did it cost?
This is where most heating comparisons go wrong. Temperature is a result. Energy consumption is an input. Without a heater-specific measured input, we can describe performance but not true running cost. We now have total battery-history data, analysed in the next chapter.
Webasto Air Top 2000 STC D
Manufacturer technical ranges for the diesel version:
| Specification | Range |
|---|---|
| Nominal heat output | 0.9–2.0 kW |
| Fuel while firing | 0.12–0.24 L/hour |
| Rated electric running draw | 14–29 W |
The ranges are published operating specifications under specified conditions, not logged readings from Vanilla. Manufacturer installation manual, technical data ↗
Living-room heating inputs
The Tado controls your oil-fired central heating with its thermostat in the hall. The DREO and Vortex provide supplementary electrical heat in the living room.
A Meross export showing kWh by timestamp would tell us what each electrical heater consumed. To assess the oil boiler separately, we would need burner runtime, fuel metering or another defensible oil-use estimate.
Without these sources we can say “warm” or “cool”, but not “cheaper per night”.
What if the Webasto fired for only part of the night?
Move the slider to choose an assumed firing fraction for the 9 hours 9 minutes between 21:00 and 06:09. The calculation multiplies assumed firing hours by Webasto's published 0.12–0.24 L/h fuel range. It deliberately doesn't claim to reconstruct the real burner cycles.
Assumed proportion of the night firing: 50%At a notional 100% continuous firing fraction, 9.15 h × 0.12–0.24 L/h gives 1.10–2.20 L. Actual operation may involve modulation, pauses, restart loads and installation-specific conditions. This slider is for understanding sensitivity, not for billing or proving efficiency.
And the battery? We now have its history.
At the stated 14–29 W rated electric running draw, nine hours and nine minutes at those draw levels equates to roughly 0.13–0.27 kWh — an illustrative running-power calculation only. Startup/glow-plug demand, varying fan speed, control pauses and other van loads can change the actual measured battery energy use.
The measurement plan that would settle it
Export minute/interval energy and power for DREO and Vortex. Ensure both monitors use the same clock and the same test night.
Use synchronized battery current/energy records for Vanilla, then account for the fridge, lighting and other simultaneous loads. A net battery trace alone cannot isolate the Webasto; see the new time-aligned battery evidence below.
A proper heater runtime/diagnostic record or trustworthy fuel measurement is needed to turn the diesel range into a real overnight consumption figure.
Log Tado calls for heat and, where possible, oil burner runtime or metered fuel use. The hall thermostat's temperature must be kept distinct from the living-room sensor.
The van was warm.
But what did the battery do?
This is the missing subplot. We've already watched the air temperatures. Now, a new 960-row battery-history export lets us follow Vanilla's electrical reserve through the same cold night. It spans 6 October to 14 November, with usable readings through 07:00 on 14 November. The data do not include an appliance-by-appliance power meter — a critical distinction.
The cabin warmed and stayed comfortable. Meanwhile, its 105 Ah LiFePO₄ leisure battery's reported state of charge moved down by 14.7 percentage points between 9pm and 6am.
That is not inherently alarming; the real question is which devices used those amp-hours. The Webasto, the compressor fridge, the control electronics and any other active circuits all share the battery budget. The file records their net effect, not separate costs.
Trace 04: Battery state of charge
The green curve shows the reported SOC at each hour. It never climbs overnight. This is an actual data trace, not a rendering invented by the AI artwork.
Vanilla lithium battery state of charge on 13 to 14 NovemberHourly state-of-charge readings declined from 86.3 percent at 8pm to 84.8 percent at 9pm, 70.1 percent at 6am, and 67 percent at 7am. Direct measurements from the uploaded battery history CSV.60%65%70%75%80%85%90%20:0022:0000:0002:0004:0006:0007:0084.8%70.1%67.0%Source: Solar History - 2026-10-06.csv. Hourly data. The source does not specify the SOC algorithm, calibration error or precise sampling method.
Charge balance, hour by hour
The file's Charge (Ah) field is negative at every hourly reading between 8pm and 7am, consistent with net discharge. The larger negative bar at 7am deserves a separate equipment check.
Hourly charge in amp-hoursAll twelve readings from 8pm to 7am are negative. The final 7am hourly value is minus 5.07 amp-hours, larger in magnitude than earlier hours.0-1-2-3-4-520:00-2.4822:0000:00-1.8402:0004:0006:00-3.1607:00-5.07The bars depict the CSV's signed hourly values. The export doesn't explain how the hours are assigned to timestamps, so these bars are not automatically a time-matched Webasto consumption trace.
How much electricity is 14.7%?
Given the nominal 105 Ah leisure battery, a 14.7-point SOC change corresponds to roughly 15.4 Ah of nominal capacity. At an assumed 12.8 V nominal battery voltage, that is about 0.20 kWh across nine hours — an average net battery draw of approximately 22 W.
0.147 × 105 Ah × 12.8 V ≈ 198 Wh
A teaching estimate, not a measured energy total. Battery SOC depends on shunt configuration, capacity assumptions and synchronisation; real voltage varies. Other loads are included. No fair comparison with mains-electricity tariffs or diesel cost follows from this number alone.
That draw wasn't the usual baseline
On the immediately preceding comparable 21:00–06:00 window, the SOC went from 99.8% to 96.8%: a fall of just 3.0 points. This night, the fall was 14.7 points.
That is a meaningful change in net battery behaviour, but it's not a controlled comparison. We don't have verified heater on/off times, solar input, alternator or hook-up status, fridge cycles, or an inventory of switched-on devices for the two nights.
A before/after difference is a lead for investigation — not proof that the Webasto consumed the difference.
What happened around 7am?
The CSV records −3.16 Ah at 6am and −5.07 Ah at 7am, compared with overnight hours more commonly around −1 to −2 Ah.
That may reflect an extra load, a change in heater operation, or the file's reporting intervals. There is no evidence here to identify the cause, and it would be poor diagnostics to label it a glow-plug event without a time-aligned heater or current log.
Best follow-up: inspect a finer-resolution SmartShunt current trace and note any switches or heater state changes around 06:00–07:00.
Four things a battery-history CSV can — and cannot — tell us
The filename says “Solar History,” but its three columns are timestamp, Charge (Ah) and SOC (%). There is no dedicated PV current, panel watts or charger-source column. Positive daytime readings cannot be credited specifically to solar.
Even a precise shunt measures the total net current through the battery. Fridge, lighting and standby electronics can all contribute. To isolate Webasto electrical use, we'd need a controlled on/off comparison or a dedicated heater current channel.
For example, the nine hourly “Charge (Ah)” entries stamped 22:00 through 06:00 sum to −16.72 Ah, while the nominal-capacity equivalent of the 21:00-to-06:00 SOC change is about 15.4 Ah. These are not necessarily measurements of exactly the same interval. Adding logged hourly values gives one figure; converting SOC change using the nominal 105 Ah gives another. They needn't agree because of timestamp boundaries, SOC estimates, capacity calibration and the export's unknown aggregation method. We should not quietly make them agree.
We know Vanilla held above 20°C overnight while outside reached 1°C. We don't know how many litres the Webasto burned, its precise firing duty cycle, or how much power was used by the heater alone. Comfort is demonstrated; efficiency is still an open measurement.
Open the original 12 hourly battery readings · 20:00–07:00
| Local timestamp | SOC | Charge field |
|---|---|---|
| Fri 20:00 | 86.3% | -2.48 Ah |
| Fri 21:00 | 84.8% | -1.43 Ah |
| Fri 22:00 | 83.3% | -1.86 Ah |
| Fri 23:00 | 81.8% | -1.43 Ah |
| Sat 00:00 | 80.1% | -1.84 Ah |
| Sat 01:00 | 78.5% | -2.26 Ah |
| Sat 02:00 | 77.0% | -1.41 Ah |
| Sat 03:00 | 76.0% | -1.34 Ah |
| Sat 04:00 | 73.2% | -1.33 Ah |
| Sat 05:00 | 72.5% | -2.09 Ah |
| Sat 06:00 | 70.1% | -3.16 Ah |
| Sat 07:00 | 67.0% | -5.07 Ah |
The label “Charge (Ah)” is preserved exactly as supplied. The export's timestamp convention and the inclusion/exclusion of partial hours are undocumented.
How trustworthy
is the evidence?
A good experiment records its limits as carefully as its wins. Here's the audit trail: what was measured, what was reported, and what we would need to claim more.
Measured directly in the CSVs
Time-stamped air temperature, relative humidity, calculated dew point and absolute humidity for Outside, Vanilla and Living Room. Data were aligned to the same minute.
Overnight interval: 21:00 Fri 13 November to 06:09 Sat 14 November 2026. 550 matching timestamp rows per sensor; 549 elapsed minutes. The common exported overlap spans 06:57 Friday to 06:09 Saturday, 1,393 rows.
Reported settings and conditions
Webasto set to 20°C. Previously reported Tado target of 20.5°C daytime and 17°C overnight, with Tado in the hall, plus DREO and Vortex supplementation. The fuel-pump bracket was reportedly still pending installation.
These details come from your description of the systems, not from the temperature files. The exact Tado program in force that night, heater cycles, window state and pop-top position weren't recorded.
The evidence ladder
| Claim | Evidence level | Why |
|---|---|---|
| Vanilla stayed at ≥20.1°C after 9pm | Measured | All 550 interior readings |
| Living room cooled from 21.7°C to 16.3°C | Measured | Matching timestamp readings |
| Webasto was regulating via pauses | Possible | Temperature dips fit the behaviour but don't log burner state |
| Webasto's thermostat is miscalibrated | Unknown | Sensor placement and actual feedback reading unknown |
| Vanilla has better insulation than the house | Not established | Different areas, heat input and heating strategies |
| Vanilla costs less to heat overnight | Not established | No comparable metered energy use |
Five upgrades for NIX Heat Lab 02
Keep conditions repeatable
Mark the SwitchBot positions and leave them unchanged. Record roof raised or lowered, any cracked windows/vents, and whether anyone was in Vanilla. Keep the next test duration and setting consistent.
Log the controls
Photograph or note the exact Webasto setting and controller, Tado setpoint and schedule start times. Record heater noise, pump clicks, fault codes and any deliberate manual changes.
Catch the missing energy
Align Meross power history, SmartShunt current and voltage data, and any Webasto diagnostic/fuel-runtime information. Add the oil boiler's runtime if feasible.
Ask the right comfort question
Not simply “which space was warmest?” — ask whether the living room felt comfortable at waking time, whether Vanilla's 22–23°C is hotter than desired, and what energy each change required.
What about measurement uncertainty and sensor placement?
Why the humidity averages are useful but not a condensation diagnosis
Sources and data provenance
- Primary evidence: Original exported SwitchBot CSVs — Outside, Vanilla and Living Room, 13–14 November 2026. The downloadable ZIP contains the unmodified files plus the timestamp-aligned temperature table.
- Webasto Air Top 2000 STC workshop manual — heater intake temperature sensing, heat modulation and control pause behaviour (section 3).
- Webasto Air Top 2000 STC installation manual — diesel heater specifications and vibration-damping fuel pump mounting (sections 8.5 and 16).
- Energy Saving Trust: heating controls — background on room thermostat setpoints and timed setbacks.
No external research was used to alter the raw measurements. Technical documents support descriptions of how the equipment is designed to work; they do not establish what actually happened during this individual test. AI-generated visuals throughout the feature are concept illustrations, not photographs or quantitative evidence.
So, who actually
won the night?
The cabin stayed between 20.1°C and 23.0°C for all 550 compared minutes, as the outdoor temperature fell.
A controlled evening-to-morning decline is plausible with the previously reported Tado night setback.
Vanilla ran about 2°C above its selected 20°C setting on average.
To compare costs, we need measured electricity use, fuel consumption or heater operating logs — not temperature alone.
Vanilla wins for overnight warmth.
Not for proven efficiency.
From a repair-confidence perspective, this was an encouraging night. The Webasto demonstrably kept the van comfortable even as the outside sensor reached 1.0°C. But there is more to learn about its thermostat response, the pump mounting and the true energy cost.
Meanwhile, the house did something very different: it cooled as the night went on. Improving when and where that heat is delivered may make the next morning feel much nicer without simply turning everything up.
What did Vanilla's roof panels
actually contribute?
We knew how the cabin felt, we knew what the outside temperature did, and we could follow the leisure battery's reported state of charge. A second file called Solar-History.csv finally tells us what the Victron solar charger harvested on each of the previous 30 complete days. The two “solar history” exports are not the same type of record: one is hourly battery SOC, and this one is the MPPT's daily photovoltaic history.
Total PV energy converted by the MPPT that day
15 October–13 November, 128.3 Wh per day on average
670 Wh in total, 25.4% lower than the 30-day mean
26% of the panels' nominal 200 W rating at that instant
Solar generation, day by day
Each bar is one complete day's recorded MPPT solar yield, not an estimate of sunlight and not a battery-charge percentage. Hover over the bars for daily readings. The final orange bar is Friday 13 November; the pale-blue bars show the latest seven complete days.
On a phone, swipe the chart sideways to examine every daily reading.
Why 120 Wh doesn't mean “120 Wh stored”
The 120 Wh is energy converted by the solar charger. It does not tell us how much remained in the leisure battery after contemporaneous loads. On a parked van, the fridge, standby electronics or other connected equipment may consume some as it arrives.
Useful mental arithmetic: 198 ÷ 120 ≈ 1.65. So the overnight nominal battery change is comparable in size to 1.65 days of Friday's PV harvest, if that energy were all available to refill the battery. In real use, loads and charging losses mean the recovery takes longer.
What did the Victron charger report?
| Friday PV peak | 52 W |
|---|---|
| PV peak voltage | 35.94 V |
| Battery voltage range | 13.04–13.56 V |
| Time labelled Bulk | 539 minutes |
| Absorption / Float | 0 / 0 minutes |
| Recorded error history | All zero in this 31-row export |
Bulk throughout the recorded charging period, with no Absorption or Float minutes, suggests the MPPT did not progress to its later charge stages that day. That does not establish the battery's absolute SOC, because the MPPT sees its own charging process, and alternator/DC-DC charging may also exist.
“Consumption: 0 Wh” does not mean Vanilla used no electricity
The history includes a field named Consumption (Wh), showing 0 Wh on Friday. This is not a whole-van energy meter. Victron's MPPT load figures monitor loads connected through the charge controller's load output; loads wired elsewhere can be invisible to it. The separate SmartShunt is the more suitable source for measuring net battery current. Victron's own explanation ↗
In other words, the zeros in this column cannot contradict the overnight fall in battery SOC. Both datasets can be perfectly consistent.
14 November's “0 Wh” isn't a failed day
Today's row was exported in the morning, before Saturday's full daylight period had occurred. At the moment of export it recorded 0 Wh yield, a maximum PV power of just 2 W, and 31 minutes in Bulk. We must exclude this incomplete day from monthly and weekly averages. A daily 0 Wh figure early in the morning is not evidence the panels stopped working.
Across the preceding 30 complete days, the daily solar yield ranged from 40 Wh (5 November) to 250 Wh (16 October). Even in the same month, cloud, low sun, vehicle orientation and shading can radically change harvest.
Three useful comparisons — and three traps
52 W is the strongest instantaneous solar reading that Friday; 120 Wh is the accumulated daily energy. They answer different questions. A 200 W panel is a nameplate test rating, not a winter output promise.
Only 5 of 30 complete days recorded any time in Float, and 6 of 30 recorded Absorption. This suggests limited solar-charging opportunity in the period, not proof that the battery was never charged by another source.
The four error-history fields were zero on every exported row. Encouraging for the charge controller; not a test of the Webasto, the entire solar installation, the panels' cleanliness or the pump mount.
Friday's 52 W peak is 26% of the 200 W nominal panel rating, but the file doesn't provide irradiance, panel temperature, cloud cover, shading, tilt or charger-limiting status. We cannot call that an underperforming array from this record alone.
The SmartShunt helps explain what changed in the battery reserve. The MPPT history reveals solar input. Neither can identify the heater's exact fuel burn or individual appliance wattage without a dedicated channel.
Record Solar MPPT power and SmartShunt net current at the same time as the Webasto's operating state, fridge cycles and cabin temperature. Then we can separate daylight replenishment from overnight demand.
Definitions checked against Victron's official SmartSolar monitoring guide. Reported figures are preserved from the export; the 198 Wh overnight comparison uses nominal assumptions and should not be treated as a watt-hour meter reading.
Open the last 14 complete days of solar-controller readings
| Date | Yield | Peak PV | Battery voltage range | Absorption / Float (min) |
|---|---|---|---|---|
| Sat 31 Oct | 120 Wh | 47 W | 13.10–14.19 V | 0 / 0 |
| Sun 1 Nov | 120 Wh | 71 W | 13.10–14.22 V | 128 / 0 |
| Mon 2 Nov | 150 Wh | 74 W | 13.08–13.81 V | 0 / 0 |
| Tue 3 Nov | 100 Wh | 62 W | 12.92–13.38 V | 0 / 0 |
| Wed 4 Nov | 140 Wh | 72 W | 12.89–13.59 V | 0 / 0 |
| Thu 5 Nov | 40 Wh | 13 W | 12.91–13.76 V | 0 / 0 |
| Fri 6 Nov | 60 Wh | 32 W | 13.16–13.79 V | 0 / 0 |
| Sat 7 Nov | 120 Wh | 37 W | 13.12–14.06 V | 0 / 0 |
| Sun 8 Nov | 110 Wh | 50 W | 13.10–14.11 V | 0 / 0 |
| Mon 9 Nov | 60 Wh | 21 W | 13.12–14.18 V | 0 / 0 |
| Tue 10 Nov | 80 Wh | 28 W | 13.08–13.87 V | 0 / 0 |
| Wed 11 Nov | 90 Wh | 53 W | 13.09–14.21 V | 41 / 52 |
| Thu 12 Nov | 90 Wh | 52 W | 13.12–14.22 V | 30 / 317 |
| Fri 13 Nov | 120 Wh | 52 W | 13.04–13.56 V | 0 / 0 |
Original export retained in the accompanying ZIP. These are Victron MPPT daily summaries, not time-matched hourly records.
Same three sensors.
One smarter test.
Vanilla, round two
Repeat the test with the Webasto at 20°C, with the SwitchBot in the same position. Note heater starts/stops, any faults, the pop-top position and battery behaviour. Have the outstanding pump mounting issue resolved.
Aim: thermostat behaviour + reliabilityLiving room, round two
Try a controlled night at an 18°C Tado setting, keeping the rest of the schedule stable. Compare morning comfort and DREO/Vortex energy use against the 17°C baseline once Meross exports are available.
Aim: comfort versus kWhThe real prize isn't the highest reading on a thermometer. It's a campervan you trust and a home that feels beautifully warm, without using more energy than necessary.
Independent personal experiment, Staffordshire, 13–14 November 2026. Temperature, relative humidity, dew point and absolute humidity from exported SwitchBot CSV files. Not laboratory-grade calorimetry or heater certification.
Story and charts built from original data.