The living room is the part of this experiment that matters most.

NIX Heat Lab model showing outside, hall and living room with Vortex
NIX HEAT LAB • LIVING ROOM EDITION

The living room is the part of this experiment that matters most.

Outside sets the challenge. The hall shows me how the house and central heating are responding. But the living room is where comfort is actually experienced — and where the Vortex adds its own measurable layer on top.

This is the version of the NIX Heat Lab story that puts the living room where it belongs: at the centre.

Living room average20.28°C
Hall average19.61°C
Living−Hall mean+0.67°C
Living warmer than hall71.9%
THE EXPERIMENT IN ONE SENTENCE

Outside creates the challenge. The hall gives me the baseline. The Vortex creates the living-room surplus.

How the experiment works
The corrected model: outside is the driver, hall is the whole-house/central-heating benchmark, living room is hall response plus Vortex.

The outside sensor tells me what conditions the building is fighting against. The hall shows how the house responds through its fabric and central heating. The living room then adds a second heating layer: the Vortex.

Living room − Hall ≈ the clearest thermal clue to the Vortex

That difference is not a perfect electrical power meter, but it is the strongest signal available in the temperature data.

WHY THE LIVING ROOM MATTERS MOST

This is the room where the experiment becomes personal.

The living room matters most
The living room is the comfort zone: same building and central heating, plus extra local heat from the Vortex.

The hall can tell me whether the house is broadly warm. The living room tells me whether I am comfortable.

That distinction is crucial. A house can be technically within a normal temperature range and still not feel particularly inviting. My living room is where I want the warmer end of comfort, and the data reflects that.

Across the entire matched dataset, the living room averages 20.28°C, compared with 19.61°C in the hall. It is warmer than the hall for 71.9% of all matched observations.

The average surplus is 0.67°C, but at times it grows to roughly 3.0°C.

The living room is not merely another sensor location. It is the experimental zone where the extra Vortex input becomes visible.
WHEN THE VORTEX SHOWS UP

The Vortex appears in the data when the living room pulls away from the hall.

When the Vortex shows up
The visual signature: hall settles near its whole-house level while the living room keeps climbing.

The most useful Vortex clue is divergence.

During the main central-heating recovery, hall and living room often rise together. That makes sense: both rooms belong to the same heated house.

But once the hall reaches roughly its normal daytime level, its curve often flattens. The living room does not always flatten with it. Instead, it continues upward towards 21, 22 or 23°C.

That extra rise is the key. It cannot easily be explained by the central heating alone if the hall has already stopped responding.

The working interpretation

Hall rising + living rising: central-heating phase.

Hall flat + living rising: strong Vortex signature.

Hall falling + living flat/higher: Vortex likely maintaining the living room after whole-house demand has reduced.

THE DAILY PATTERN

The living room gains its extra advantage through the day.

At around 05:00, the average temperatures of living room and hall are almost identical: 18.83°C and 18.82°C. Overnight, the Vortex advantage has largely faded.

By noon, the living room averages 21.13°C while the hall is around 19.99°C.

By 17:00, the average difference has widened to roughly 1.32°C.

That is exactly the pattern this experiment predicts: the house reaches its general comfort level first, and then the living room becomes the warmer zone.

THE NIGHT-TIME RESET

At night, the Vortex effect fades and the rooms move back together.

Night-time reset infographic
Night removes much of the local-heating surplus, allowing living room and hall to converge.

Across the latest ten complete nights, the hall cools by an average of 2.01°C between 21:00 and 06:00. The living room cools by 3.08°C.

The living-room drop is larger because it usually starts warmer. That is not automatically evidence of poorer insulation. It is largely what we should expect when the room begins the night with additional Vortex heat.

As that extra input disappears, the living room gives up its surplus and moves back towards the hall.

The overnight convergence is not a problem in the model. It is one of the strongest pieces of evidence that the daytime living-room surplus is local heating.
OUTSIDE STILL SETS THE DIFFICULTY

The Vortex can change comfort. It cannot change the weather.

Outside remains the main external driver. When outdoor temperature falls, both the hall and living room face a larger heat-loss gradient.

The lowest matched outdoor temperature in the dataset is 6.4°C. At that moment, the hall was still 19.28°C and the living room was 18.50°C.

The important question is therefore not whether the outside temperature changes — it always will. The question is how much heating input is needed to keep the hall stable and how much additional Vortex input is needed to push the living room to the comfort level I want.

THE COMFORT RESULT

The living room is warmer by design — and the data proves it.

Living room >22°C17.6%of matched time
Hall >22°C0.9%of matched time
Living RH average51.1%
Living RH 40–60%98.2%

The living room spends significantly more time at the warmer end of the comfort range than the hall. That is not accidental noise; it is a consistent pattern.

Humidity remains exceptionally well controlled at the same time, which means the room is not achieving comfort by becoming excessively dry or damp.

WHAT THIS ACTUALLY PROVES

The current data supports the model strongly — but direct power telemetry would finish the job.

The temperature data supports three conclusions:

1. Outside temperature is the external condition that determines how hard the building is being challenged.

2. The hall behaves like a whole-house / central-heating benchmark.

3. The living room develops a repeatable surplus over the hall that is consistent with the additional Vortex heat input.

What the temperature data cannot do is tell me the exact second the Vortex relay switched on or off. For that, a smart plug with power logging would provide direct ground truth.

The next level

Pair the living-room temperature trace with actual Vortex watts. Then every rise, plateau and fall can be matched against real heater activity, allowing the Vortex contribution to be quantified rather than inferred.

OUTSIDE SETS THE CHALLENGE.
THE HALL SHOWS THE HOUSE. THE LIVING ROOM SHOWS THE VORTEX.
THE SIMPLE VERSION

The whole experiment in four lines.

🌦️ Outside: the main external driver I cannot change.

🚪 Hall: the central-heating and whole-house benchmark.

🛋️ Living room: the same house response, plus the Vortex.

🔥 Living room − Hall: the clearest thermal clue to the Vortex effect.

And that is why the living room deserves the starring role in this experiment.

Heating and Vortex states are inferred from temperature behaviour until direct power telemetry is added.